X-ray diffraction (XRD) analysis
XRD identifies the crystalline phases in a material and measures how much of each is present. Sietronics provides qualitative and quantitative XRD for mining, geotechnical, research and industrial samples, with quantification by Rietveld refinement in Siroquant.
What is XRD analysis?
X-ray diffraction is a non-destructive technique for characterising materials. It is the most direct method for identifying crystalline compounds and their percentages.
Where chemical analysis tells you which elements are in a sample, XRD tells you which minerals and compounds those elements form. That difference matters whenever behaviour depends on mineralogy rather than chemistry: clay type, silica polymorph, or ore and gangue phases.
Which XRD services do you offer?
Five analyses, each answering a different question. If you are unsure which applies, describe the problem and we will recommend one.
Qualitative phase analysis
Which crystalline phases are present?
Identifies the crystalline phases in your sample.
Quantitative phase analysis
How much of each mineral is there?
Determines mineral percentages using Rietveld refinement in Siroquant.
Amorphous content
How much of the sample is non-crystalline?
Measures the non-crystalline material, such as glass or amorphous phases in bauxite. Normally done by the internal standard (spike) method; the external standard method is also available.
Clay speciation and quantification
Which clay minerals, and in what proportions?
Follows USGS guidelines, with glycolation and heat treatments at 400°C and 550°C. Covers kaolinites, smectites and illites.
Respirable crystalline silica (RCS)
Does this engineered stone contain crystalline silica?
Tests respirable crystalline silica in engineered stone, and separates the SiO2 polymorphs quartz, cristobalite and tridymite.
How is a quantitative XRD analysis done?
- Step 1 Prepare Samples are pulverised in a ring mill. Optional: micronising in a McCrone mill to below 4 µm. Optional: for amorphous content, adding a weighed internal standard (spike).
- Step 2 Measure The powder pattern is collected on a Bruker D8 ENDEAVOR or D2 diffractometer.
- Step 3 Identify Peaks are matched to reference patterns to identify each crystalline phase.
- Step 4 Quantify The whole pattern is refined in Siroquant to calculate the percentage of each phase.
- Step 5 Report You receive a report of the phases found and their proportions.
Which instruments do you use for XRD?
Patterns are collected on two Bruker diffractometers, with dedicated mills for sample preparation.
Bruker D8 ENDEAVOR
- Powder X-ray diffraction system
- Dynamic Beam Optimisation, with no manual reconfiguration
- LYNXEYE XE-T detector
- Fast, with low detection limits
Bruker D2
- For production and research samples
- Lynxeye detector
- Sample loader for high throughput
Sample preparation
- Rocklabs standard ring mill: up to 1000 g, to below 75 µm
- Rocklabs benchtop ring mill: steel and tungsten carbide heads
- McCrone micronizing mill: to below 4 µm, designed for XRD
What materials can be analysed by XRD?
Nearly any solid. These are the applications we handle most often.
Geological samples
Ore and gangue identification, mineral sands from ore to concentrate, core and borehole mineralogy, coal mineralogy and coal ash, amorphous material in bauxites.
Clays
Kaolinites, smectites and illites. Halloysite can be identified by XRD and, if needed, SEM.
Concrete and cement
Identification and quantification of free lime, cement kiln dust and fly ash for quality control.
Industrial and metallurgical
Scale and pipe build-up, corrosion products, ceramics, refractory bricks, paints and pigments, geosynthetic clay liners, diatomaceous earth, process metallurgy.
Occupational health and safety
Respirable crystalline silica in engineered stone, SiO2 polymorphs and air filter dust.
Pharmaceuticals
Quality control, polymorph identification, API confirmation and contaminant identification.
How much sample does XRD need, and how long does it take?
Routine XRD needs about 1 g of sample and takes 1–2 weeks from receipt. Results in 24–48 hours may be available for an extra charge.
| Analysis | Sample required | Standard turnaround |
|---|---|---|
| XRD, crystalline minerals | About 1 g | 1–2 weeks |
| XRD, limited material | Milligrams, on a zero-background holder | 1–2 weeks |
| XRD, clay analysis | About 20–60 g, depending on clay percentage | 1–2 weeks |
| Expedited XRD | As above | 24–48 hours, extra charge |
Before you send samples: email or phone the lab, and include a purchase order or test request form listing sample numbers and tests. How to submit samples
XRD questions
Can XRD always identify what is in a sample?
Usually, but not always. Samples with high amorphous content or overlapping peaks can be hard to identify. In those cases XRF, SEM or FTIR can help.
What is the difference between XRD and XRF?
XRF measures elements, roughly fluorine to uranium, in percent or parts per million. XRD identifies the crystalline compounds those elements form. Using both improves phase identification and quantification.
Is XRD destructive?
No. It generally needs a powdered sample, ground to about 50 microns or finer.
Can you run XRD on a very small sample?
Yes. Zero-background holders accept milligram-sized samples.
What is the detection limit of XRD?
It depends on the phase and on the sample matrix, so there is no single figure. Tell us which phase matters and what the sample is made of, and we will advise what can be detected.
Request a quote
Tell us what the samples are and what you need to know. If you are unsure which test fits, describe the problem and we will recommend one.
+61 2 6246 9299 lab@sietronics.com.au 40 Hoskins Street, Mitchell ACT 2911